Free CHMM flashcards

12 flashcards from the Planning for Materials with Hazards domain. Read the front, show the answer, then grade yourself. Cards you miss come back sooner when you return to this page. No signup.

0 due today12 to learn12 cards

Flashcard · Planning for Materials with Hazards

Which SDS section gives flash point, pH and vapor pressure?

Print these cards (PDF) · cut-out sheets: print double-sided, flip on the long edge

Send these free cards to a coworker.

The course has 160 cards with spaced review.It also adds every question you miss to your deck.

Terms and refunds · Secure checkout by Stripe · Billed by Nori Software

Not sure where to start? Take the free 10-question check.

All 12 cards

The same signed cards as the trainer above, in one list to read or print.

Which SDS section gives flash point, pH and vapor pressure?
Section 9, physical and chemical properties.29 CFR 1910.1200(g)(2)
Which SDS section lists ingredients and their concentrations?
Section 3, composition and information on ingredients.29 CFR 1910.1200(g)(2)
Which SDS sections does OSHA not enforce?
Sections 12 to 15 (ecological, disposal, transport, regulatory). They are part of the format but outside OSHA's jurisdiction.29 CFR 1910.1200(g)(2)
RCRA ignitability line for a liquid waste?
Flash point below 60 °C (140 °F): code D001.40 CFR 261.21(a)(1)
RCRA corrosivity line for an aqueous waste?
pH of 2 or less, or 12.5 or more: code D002.40 CFR 261.22(a)(1)
Is a TCLP result equal to the regulatory level toxic?
Yes. At or above the level is toxic.40 CFR 261.24(a)
Pollution prevention hierarchy, best to worst?
Source reduction, recycling, treatment, disposal.Pollution Prevention Act policy (concept)
Order of a pollution prevention opportunity assessment?
Plan and organize, assess, analyze feasibility, implement, then measure and sustain.PPOA practice (concept)
Is holding a material for years in case it can be sold someday recycling?
No. Without a real market and use, it is speculative accumulation, not recycling.Legitimate recycling (concept)
What usually separates a major permit from a minor one?
Source size or potential impact, often potential emissions in tons per year; major permits bring more monitoring, public involvement and review time.Permitting (concept)
Main steps of a permit review?
Application, completeness review, technical review, draft permit with public notice and comment, final permit.Permitting (concept)
RMP threshold quantities for anhydrous ammonia, chlorine and propane?
Ammonia (anhydrous) 10,000 lb; chlorine 2,500 lb; propane 10,000 lb.40 CFR 68.130