UT skip-distance calculator: angle beam, full and half skip

Find the surface distance and sound path for a refracted angle beam in a flat plate. Locate a reading on the first or second leg and explore how wedge velocity changes the beam angle.

Calculate the beam path

Results update as you type. All angles are measured from the surface normal.

Distances at 60°

Half skip · surface distance
43.3013 mm
Full skip · surface distance
86.6025 mm
Half-skip sound path · one leg
50 mm
Full-skip sound path · V-path
100 mm

Reading position: leg 2

Depth below entry surface: 12.5 mm.
Surface distance from beam entry: 64.9519 mm.

Depth = 2T − SP × cos θ. The exact backwall point is assigned to leg 1; the full-skip endpoint is assigned to leg 2.

Angle beam path through a flat plateBeam at 60 degrees from normal travels down on leg 1, reflects at the backwall, and returns to the top on leg 2. Thickness 25 mm, full skip 86.6025 mm. Reading on leg 2: depth 12.5 mm, surface distance 64.9519 mm.Entry → full skip: 86.6025 mmθ = 60° from normal (dashed)Backwall · T = 25 mm
Leg 1: entry to backwall. Leg 2: backwall to top. The outlined marker shows the sound-path reading. The plate and beam use the same scale; extreme angles can flatten or narrow the drawing.

One page with your plate and angle, half and full skip, and the sound path and surface distance at each quarter depth on both legs, with lines for the part, the probe and who checked it.

Angle beam skip sheet

Part or weld
Probe and wedge
Checked by
Date
Setup
Thickness T25 mm
Refracted angle θ60° from normal
Angle fromEntered
Skip distances
DistanceValue (mm)
Half skip, surface distance43.3013
Full skip, surface distance86.6025
Half-skip sound path, one leg50
Full-skip sound path, V-path100
Depth marks on legs 1 and 2
LegDepthDepth (mm)Sound path (mm)Surface distance (mm)
10 (entry)000
1T/46.2512.510.8253
1T/212.52521.6506
13T/418.7537.532.476
1T (backwall)255043.3013
23T/418.7562.554.1266
2T/212.57564.9519
2T/46.2587.575.7772
20 (entry)010086.6025

Reading: sound path 75 mm is on leg 2, 12.5 mm deep and 64.9519 mm from the beam index point along the surface.

Half skip = T × tan θ. Full skip = 2T × tan θ. One leg = T ÷ cos θ. Leg 1 depth = SP × cos θ; leg 2 depth = 2T − SP × cos θ. Surface distance = SP × sin θ.

Angles are from the surface normal. Distances run from the beam index point. Flat, parallel-sided plate, legs 1 and 2 only. Check against your approved procedure and your calibration.

Formulas and the two legs

T is plate thickness; θ is the refracted angle from the normal inside the test material. SP is the accumulated one-way sound path from the beam entry point to the reflector. Lengths use one consistent unit. The V-path follows both legs to the next top-surface intersection; it is not the round-trip echo distance back to the probe.

  • Half skip (surface distance) = T × tan θ.
  • Full skip (surface distance) = 2T × tan θ.
  • Half-skip sound path = T / cos θ.
  • Full-skip sound path (V-path) = 2T / cos θ.
  • Surface distance for a reading = SP × sin θ.
  • Leg 1 depth = SP × cos θ, for 0 ≤ SP ≤ T / cos θ.
  • Leg 2 depth = 2T − SP × cos θ, for T / cos θ < SP ≤ 2T / cos θ.

These are right-triangle derivations using the equal-angle reflection geometry described in Evident's An Introduction to Ultrasonic Flaw Detection. For leg 2, the beam has already crossed the thickness T; its upward travel is SP × cos θ − T. Subtract that upward travel from T to get 2T − SP × cos θ.

Press Print skip sheet under the diagram to get one page for your plate and angle: half and full skip, both sound paths, and the depth, sound path and surface distance at each quarter of the thickness on leg 1 and leg 2. It has lines for the part or weld, the probe and wedge, who checked it and the date, plus a link that reopens the same numbers. Save it as a PDF from the print dialog, keep it beside the flaw detector or work it on paper for UT Level II.

Worked example: 25 mm plate at 60°

Half skip = 25 × tan 60° = 43.3013 mm; full skip = 86.6025 mm. One leg is 25 / cos 60° = 50 mm; the V-path is 100 mm.

A 75 mm sound-path reading lies on leg 2 because 50 < 75 ≤ 100. Its surface distance is 75 × sin 60° = 64.9519 mm. Its depth is 2 × 25 − 75 × cos 60° = 12.5 mm below the top surface. Applying the leg 1 formula here would incorrectly place the reflector below the backwall.

Second example: 20 mm plate at 45°

Half skip = 20 × tan 45° = 20 mm; full skip = 40 mm. One leg is 20 / cos 45° = 28.2843 mm; the V-path is 56.5685 mm. A 40 mm sound-path reading lies on leg 2. Its surface distance is 40 × sin 45° = 28.2843 mm and its depth is 2 × 20 − 40 × cos 45° = 11.7157 mm. These numbers are invented for practice. The same formulas are on the UT and MT formula sheet.

Snell's law and critical angles

For an incident longitudinal wave in the wedge and a refracted shear wave in the plate, sin α / cW = sin θ / cS. Rearranging gives θ = arcsin[(cS / cW) × sin α]. Here α is the incident angle from normal, cW is wedge longitudinal velocity, cS is material shear velocity, and cL is material longitudinal velocity. The calculator substitutes your numbers above.

At a critical angle the relevant refracted ray reaches 90°. Setting its sine to 1 gives αc1 = arcsin(cW / cL) for the first (longitudinal) critical angle and αc2 = arcsin(cW / cS) for the second (shear) critical angle. A ratio greater than 1 means that critical angle does not exist for the entered velocities. At or beyond the second critical angle, this tool suppresses the through-thickness shear-path results.

Source: Evident, Ultrasonic Flaw Detection Tutorial: 2.5 Wave Front Dynamics. This is a ray model; it does not calculate beam spread, transmission amplitudes or surface-wave paths.

Assumptions and use limits

Use a flat, parallel-sided plate with a uniform, isotropic velocity and a calibrated angle and beam index point. This tool supports only the first two legs. Curved surfaces, anisotropy and mode conversion at reflections need a different model. Reference velocities are starting values, not a calibration: confirm the material, temperature and actual wedge velocity against your procedure.

Skip-distance calculator FAQ

How do I find half skip and full skip?

Half skip is plate thickness times tan θ, and full skip is twice that. For a 25 mm plate at 60°, half skip is 25 × tan 60° = 43.3013 mm and full skip is 86.6025 mm. Use one unit for every length.

Is the V-path the same as the echo distance back to the probe?

No. The V-path follows both legs to the next top-surface intersection, 2T / cos θ. In the 25 mm, 60° example one leg is 50 mm and the V-path is 100 mm. It is not the round-trip echo distance.

How do I tell whether a sound-path reading is on leg 1 or leg 2?

Compare the reading with one leg, T / cos θ. In the 25 mm, 60° example one leg is 50 mm, so a 75 mm reading lies on leg 2 because 50 < 75 ≤ 100. Its depth is 2 × 25 − 75 × cos 60° = 12.5 mm. The leg 1 formula would wrongly put that reflector below the backwall.

Why are the through-thickness results missing at a large angle?

At or beyond the second critical angle the calculator suppresses the through-thickness shear-path results. The second critical angle is arcsin(cW / cS), and it does not exist if that ratio is greater than 1. Check the wedge and material velocities you entered.

Get half skip, full skip, V-path and reflector depth with a beam diagram that updates as you type. A study aid; your own documents, procedures and the AHJ govern real work.

Try one free question

Try one question

Question 1 of the free 10-question check on UT L2. No signup. Then ask Echo, the AI study assistant, why the answer is right and the others are wrong.

Question 1 of 10 · free checkUntimed

Discontinuity Detection

A planar reflector gives its highest echo amplitude when the beam strikes it

Press A-D or 1-4 to choose an answer while this question is on screen.

Choose an answer to begin

Free UT L2 study plan

A week-by-week plan from today to your exam, weighted to the published exam outline. We show it here and email you a copy.

Ask Echo before you buy AI your AI study assistant

See what's on the UT L2 exam, test yourself with 5 quick questions, or find the plan that fits you.

Terms this tool uses

Published references

The selected material presets use Table 2's m/s values: steel 1020 (shear 3240, longitudinal 5890), aluminum (3130, 6320), and titanium Ti 150A (3120, 6100). The acrylic wedge default is longitudinal 2730 m/s.

Print the UT and MT Level II formula sheet (free PDF, one page) and the worked guide.

From the blog

Practice UT Level II fundamentals

You just found half and full skip for your probe angle and thickness. The free 10-question check shows which Level II topics to fix first, no signup. The Angle Beam course drills them and explains every answer.

Take the free 10-question NDT Level II check

Explore the UT Level II General exam guide

The UT L2 course

Available now · instant access

The UT L2 course

  • 7modules of lessonsEvery task on the outline
  • 5full-length timed exams50 questions in 120 minutes each
  • 387practice questionsEach one explained
  • 5worked calculationsStep by step
  • 1week-by-week study planSet to your exam date

Turn a practice answer into a study step. In untimed practice, ask Echo AI about any question you answer, follow up, then see your weakest topics and what to drill next.

NDT UT Level II General course$149

Terms and refunds · Secure checkout by Stripe · Billed by Nori Software

See the course

Compare plans

Every answer comes with a full explanation.

By the Angle Beam editorial team. Report an error.

Add this calculator to your site

Copy this HTML into your page. It embeds the calculator with an attribution link and adds no external script tag.